BRHSLIST
[Top] [All Lists]

Re: [CBQ] Dynamic Brakes

To: CBQ@groups.io
Subject: Re: [CBQ] Dynamic Brakes
From: "John Olson" <trains28@jimsjunction.com>
Date: Sat, 29 Feb 2020 09:42:05 -0700
Delivered-to: unknown
Delivered-to: archives@nauer.org
Delivered-to: mailing list CBQ@groups.io
Dkim-signature: v=1; a=rsa-sha256; c=relaxed/simple; d=groups.io; q=dns/txt; s=20140610; t=1582994532; bh=WZvtX1tRdEO6yhtnPqufLoJw/bz3wcgtPdTOqHCtp6M=; h=Content-Type:Date:From:Reply-To:Subject:To; b=q0BkhDKD+ijHP6cfAARJX1cFv7zMtmtZug7aaTVK5Cu6CiqwiIecY8wgvmIEidLN3SM polfTF2/oXB00eY5OoXn5+FU0MKJlmtxzbdmHQu7+wjeZi3Y54kbQuC4IfTqXAT7ZYTGt uGoWtpOfCeX2Qo4EKxSh6SwdSb6+EBsOe+Q=
In-reply-to: <13342.1582926982594548284@groups.io>
List-id: <CBQ.groups.io>
List-unsubscribe: <https://groups.io/g/CBQ/unsub>
Mailing-list: list CBQ@groups.io; contact CBQ+owner@groups.io
References: <88ec31ec-d289-b8c9-10ad-5f22f850478f@jimsjunction.com> <13342.1582926982594548284@groups.io>
Reply-to: CBQ@groups.io
Sender: CBQ@groups.io
User-agent: Mozilla/5.0 (Windows NT 10.0; WOW64; rv:68.0) Gecko/20100101 Thunderbird/68.5.0

Tom,

   I figured that this would be the case, but I was not absolutely sure, and wondered if a DB signal might send a non-DB unit into a tizzy trying to figure out what was going on!

 John Olson

 Billings, Mt.



On 2/28/2020 2:56 PM, Tom Mack via Groups.Io wrote:
On Fri, Feb 28, 2020 at 11:41 AM, John Olson wrote:
Since all of the Q's freight F-units (including FT's) were delivered with Dynamic Brakes and none of the GP-7's or GP-9's were- when the 'Q' spliced one or more of these GP's in the middle of a 4-unit set of F's, for extra horsepower, could the Dynamic Brakes still be used... and would it  activate on all four of the F-units?
Yes. Dynamic braking is controlled on MU cable pins 17 (Dynamic Brake Control), 20 (Dynamic Brake Warning), 21 (Dynamic Brake Interlock), and 24 (Dynamic Brake Excitation). All units with MU, whether they have DB or not, should pass all MU signals through. Thus a non-DB unit would not affect the DB on any other units in the string.

The problem is if you have a non-DB equipped diesel leading a consist with DB equipped locomotives. In that case you disable DB on the entire consist since the non-DB equipped unit does not have the DB lever or wiring to control DB. Hence very seldom would a railroad that counted on DB put a non-DB unit in the lead.
 
--
Tom Mack
Cincinnati, OH
-- 
John Olson- owner

Jim's Junction
811B 16th St. West
Billings, Mt 59102

406-259-5354
<trains28@jimsjunction.com>
See us on FACEBOOK @ Jim's Junction
See us on GOOGLE @ Jim's Junction
_._,_._,_

Groups.io Links:

You receive all messages sent to this group.

View/Reply Online (#59047) | Reply To Group | Reply To Sender | Mute This Topic | New Topic

Your Subscription | Contact Group Owner | Unsubscribe [archives@nauer.org]

_._,_._,_
<Prev in Thread] Current Thread [Next in Thread>